Alat water blanket warmer adalah perangkat medis yang digunakan untuk mengatur suhu tubuh pasien dengan menggunakan selimut yang dihangatkan. Hipotermia adalah kondisi dimana mekanisme pada tubuh untuk pengaturan suhu kesulitan mengatasi tekanan suhu dingin. Hipotermia terjadi bila terjadi penurunan suhu inti tubuh dibawah 35°C. Tujuan penelitian ini adalah untuk menguji ketepatan pembacaan se…
PROGRAM SARJANA TERAPAN PRODI TEKNOLOGI RADIOLOGI PENCITRAAN JURUSAN TEKNIK RADIODIAGNOSTIK DAN RADIOTERAPI POLTEKKES JAKARTA II SKRIPSI, 2024 BRILLIYAN IBNU BAKTI PERBANDINGAN DOSIS TARGET DAN ORGAN AT RISK MENGGUNAKAN TEKNIK VOLUMETRIC MODULATED ARC THERAPY DENGAN PARTIAL ARC, SINGLE ARC, DOUBLE ARC PADA KANKER PAROTIS V Bab + 43 Halaman + 12 Gambar + 18 Tabel + 14 Lampiran Latar…
EVALUASI DISTRIBUSI DOSIS VOLUME TARGET DAN ORGAN AT RISK PADA KANKER NASOFARING DENGAN TEKNIK VOLUMETRIC MODULATED ARC THERAPHY (VMAT) V BAB + 55 halaman + 17 Gambar + 10 Tabel + 13 Lampiran Latar belakang: Pengobatan radioterapi pada kanker nasofaring dapat menyebabkan adanya peningkatan risiko penurunan dosis pada jaringan kanker, peningkatan dosis pada organ at risk (OAR), serta peningka…
Darah merupakan salah satu bagian tubuh manusia yang sangat penting. Jika terjadi kekurangan darah pada tubuh manusia baik itu karena kecelakaan atau penyakit, maka hal tersebut akan membahayakan kesehatan bahkan nyawa manusia. Salah satu penyakit kekurangan darah adalah anemia. Pengobatan kondisi ini bervariasi tergantung pada penyebabnya. Namun, apabila sudah memasuki tahap anemia berat, peng…
TEKNIK PENGUKURAN INTRAVESICAL PROSTATIC PROTRUSION PADA PEMERIKSAAN ULTRASONOGRAFI PROSTAT KASUS BENIGN PROSTATIC HYPERPLASY DI RSUD KABUPATEN BEKASI 5 Bab + 53 Halaman + 28 Gambar + 2 Tabel + 5 Lampiran Ultrasonografi ( USG ) merupakan salah satu modalitas imaging yang sangat efektif untuk membantu menegakkan diagnosa pada kasus Benign ProstaticHyperplasy ( BPH ). Melalui Transabdominal U…
“EVALUASI PENGUKURAN VOLUME CAIRAN OTAK PADA MULTI SLICE COMPUTED TOMOGRAPHY SCAN DENGAN PENDEKATAN 6 RUMAH SAKIT DI DAERAH JAKARTA DAN SEKITARNYA” V BAB, 53 Halaman, 24 Gambar, 10 Tabel, 4 Bagan Tujuan penelitian tentang Analisis Pengukuran Prototype Volume Secara Manual dan Digital Menggunakan Pesawat Computed Tomography Scan yang bertujuan untuk menguji cara pengukuran yang efektif …
vii 8. Kepada seluruh pihak yang telah membantu baik secara langsung maupun tidak langsung. Penulis, Gita Herista P2.31.38.1.13.018 ABSTRAK Gita Herista, “Kajian Teknis pada Alat Ventilator yang melebihi usia teknis di Rumah Sakit X” dibawah bimbingan Bapak Ir. H. Budhiaji, MM, 2016, Halaman + + lampiran Penelitian ini di latar belakangi oleh keingintahuan terhadap faktor yang da…
Kanker adalah pertumbuhan tumor yang bersifat ganas, berasal dari salah satu tipe sel di dalam bronkus. Perkembangan sel ini dapat menyebar ke luar dari paru-paru lewat proses metastasis ke jaringan yang terdekat, bila tidak di rawat dengan baik. Perkembangan teknologi untuk menangani kasus kanker di bidang radioterapi adalah dengan menggunakan teknik penatalaksanaan radioterapi Di Departemen …
ANALISIS PENGGUNAAN VOLUME RENDERING TECHNIQUE (VRT) PADA CT SCAN THORAX DENGAN KASUS COVID-19 DI RUMAH SAKIT UMUM DAERAH CILEUNGSI V Bab + 30 Halaman + 15 Gambar + 3 Tabel + 18 Lampiran Latar belakang penelitian adalah pasien yang terkonfirmasi virus Covid-19 dangan hasil pemeriksaan CT Scan terdapat gambaran awal yang dikenal sebagai ground glass opacities (GGO). Modalitas CT Scan terdapat …
Infusion pump merupakan alat life support yang sering digungakan di ruangan perawatan intensif. Kalibrasi infusion pump menggunakan alat standar yaitu Infusion Device Analyzer(IDA). Alat digunakan untuk mengukur flowrate dan tekanan occlusion pada infusion pump. IDA yang merupakan standar untuk mengkalibrasi infusion pump juga harus dikalibrasi minimal setahun sekali. Saat di lapangan seringkal…
Penelitian ini bertujuan untuk mengevaluasi teknik pengukuran Volume Ventricle pada pemeriksaan MRI Jantung potongan Short Axis dengan kasus Congestive Heart Failure (CHF) di RS Jantung dan Pembuluh Darah Harapan Kita. Desain penelitian yang digunakan adalah deskriptif kualitatif dengan metode observasi yang dilakukan dari bulan Februari – April 2018 di RS Jantung dan Pembuluh Darah Harapan …
INTISARI PROGRAM STUDI SARJANA TERAPAN TEKNIK RADIODIAGNOSTIK DAN RADIOTERAPI POLITEKNIK KESEHATAN KEMENTRIAN KESEHATAN JAKARTA II SKRIPSI, 2019 ALFINDA RIANI FIRDAUS TEKNIK PENYINARAN RADIASI EKSTERNA METODE VOLUMETRIC MODULATED ARC THERAPY PADA KANKER ASTROCYTOMA DI DEPARTEMEN RADIOTERAPI RUMAH SAKIT KANKER DHARMAIS 5 BAB + 49 Halaman + 23 Gambar + 1 Tabel + 12 Lampira…
Alat pengisian obat cair ini adalah alat yang digunakan untuk mempermudah dalam pengisian obat cair sesuai dengan volume setting yang diinginkan. Dalam fungsinya alat ini bekerja untuk menghitung volume obat dan menempatkannya ke dalam botol secara bergantian dan otomatis sesuai yang diinginkan. Penulisan karya tulis ini bertujuan untuk dapat merancang dan membuat alat pengisian obat cair ke da…
Pembesaran kelenjar prostat ini merupakan salah satu masalah geniutorinari yang prevalensi dan insidennya meningkat seiring dengan bertambahnya usia. Insiden Benign Prostatic Hyperplasia (BPH). Pada pemeriksaan ultrasonografi transabdominal, dapat diketahui berapa volume prostat dan besarnya protrusi prostat ke dalam buli-buli, yang dapat dipakai untuk meramalkan derajat sumbatan, dan dapat d…
Verifikasi merupakan hal yang sangat penting dilakukan untuk memastikan lapangan penyinaran supaya ketepatan penyinaran dan prinsip radioterai dapat tercapai. Verifikasi pada kasus kanker paru Teknik VMAT (Volumetric Modulated Arc Therapy) dilakukan dengan setiap hari menggunakan On Board Imager (OBI) dan setiap kelipatan lima menggunakan CBCT (Cone Beam Computed Tomography. Tujuan penelti…
ASRI DESTIANA PENATALAKSANAAN RADIOTERAPI KANKER PAYUDARA BILATERAL DENGAN MENGGUNAKAN TEKNIK VMAT (VOLUMETRIC MODULATED ARC THERAPY) DI INSTALASI RADIOTERAPI RUMAH SAKIT KANKER DHARMAIS V BAB + 46 halaman + 22 gambar + 2 tabel + 10 lampiran Teknik radioterapi banyak ada perkembangan, salah satunya adalah teknik VMAT (Volumetric Modulated Arc Therapy). Di Instalasi Radioterapi Rumah…
M. Alif Kodratullah, “Analisa Akurasi Dan Kehandalan Ventilator Covid19 Produksi Dalam Negeri Pada Pengujian dan Kalibrasi Produk Dengan Metode Rapidly Manufactured Ventilator System” , di bawah bimbinganIr. Andy Sambiono,M.Kes. 2021, 60 halaman + 2lampiran Seiring dengan terjadinya pandemi covid 19 serta terbatasnya ketersediaan peralatan bantu pernapasan khususnya ventilator, maka pemeri…
Abstract Haemorrhagic Stroke is a common disease in Indonesia. The best imaging modality for this disease is Multi Slice Computed Tomography Scanning (MSCT), as it may help strengthening the diagnosis as well as determining the brain bleeding volume. This study aimed to show correlation between bleeding volume of the brain and patient’s age using cross-sectional approach. The 68 sampl…
Abstract Introduction: Signal to noise ratio (SNR) is one of the determining factors of MRI images quality. SNR is defined as the ratio of the intensity of an object signal seen with noise. There are several factors that can affect SNR, one of them is the radiofrequency coil. Knee MRI examination based on the literature using a Knee coil with the shape of the volume. While in some hospit…
Abstract Introduction: Signal to noise ratio (SNR) is one of the determining factors of MRI images quality. SNR is defined as the ratio of the intensity of an object signal seen with noise. There are several factors that can affect SNR, one of them is the radiofrequency coil. Knee MRI examination based on the literature using a Knee coil with the shape of the volume. While in some hospit…
Background: Cardiac MRI examination is relatively rare in Indonesia. The effect of the use of volume shim on moving organs, such as the heart is relatively unknown and noticed by radiographers and cardiologists. Objective: To analyse the image quality of 4 chamber sections of Cardiac Magnetic Resonance Imaging with and without the use of shim volume on Steady State Free Precession (SSFP) sequen…
ABSTRACK This study aims to analyze the difference in results between TPS 3D-CRT radiotherapy irradiation technique and IMRT radiotherapy irradiation technique in nasopharyngeal cancer cases based on the doses received by the target volume and organs at risk and results of isodosis curve which include the value of the index conformity and homogeneity index value. Type of this research is…
ABSTRAK PROGRAM STUDI DIPLOMA 4 TEKNIK RADIODIAGNOSTIK DAN RADIOTERAPI POLITEKNIK KESEHATAN KEMENTERIAN KESEHATAN JAKARTA II SKRIPSI, 2019 DONI ANDRIAN ANALISIS PENGUKURAN VOLUME CAIRAN DENGAN MODALITAS ULTRASONOGRAFI DI RUMAH SAKIT WILAYAH DKI JAKARTA Xii V Bab + 35 Halaman + 17 Gambar + 6 Tabel + 52 Lampiran Penelitian ini bertujuan untuk mengevaluasi tingkat akurasi dari …
SKRIPSI, 2019 ADE ROCHIMAT ANALISIS ESTIMASI VOLUME CAIRAN EFUSI PLEURA MENGGUNAKAN MODALITAS USG TERHADAP TINDAKAN PUNGSI PLEURA DI RSUD CENGKARENG V Bab, 41 Halaman, 22 Gambar, 7 Tabel, 6 Lampiran Penelitian ini bertujuan untuk menganalisis teknik scanning estimasi volume cairan efusi pleura dengan modalitas USG di RSUD Cengkareng, mengukur estimasi volume cairan efusi pleur…
SHERIN HIMMATUS SUROYYA ANALISIS EMBOLI PARU MENGGUNAKAN DUAL ENERGY LUNG PERFUSION BLOOD VOLUME CT ANGIOGRAFI PULMONAL PADA PESAWAT DUAL SOURCE CT SCAN V Bab + 46 Halaman + 24 Gambar + 6 Tabel + 11 Lampiran Latar belakang: Protokol pemindaian berbasis DECT pemindaian dengan CT sumber ganda, direkomendasikan untuk perfusi paru, protokol bertujuan untuk mengevaluasi arteri pulmonalis dan per…
ABSTRAK Telah dilakukan penelitian tentang Analisis Penggunaan Variasi Coil Terhadap Kualitas Citra MRI Genu dengan penghitungan Region Of Interest (ROI). Penelitian ini bertujuan untuk mengetahui Nilai Signal Noise Ratio (SNR) citra MRI Genu menggunakan volume coil dan surface coil dan penerapan penggunaan volume coil dan surface coil pada pemeriksaan MRI Genu. Metode penelitian desain penel…
TEKNIK RADIOTERAPI VOLUMETRIC MODULATED ARC THERAPY (VMAT) PADA KASUS KANKER BIBIR DI DEPARTEMEN ONKOLOGI RADIASI MRCCC SILOAM SEMANGGI 5 BAB+ 54 Halaman + 12 Gambar + 3 Tabel + 11 Lampiran Teknik Radioterapi kini makin berkembang, salah satunya yaitu teknik terapi radiasi Volumetric Modulated Arc Therapy (VMAT) di Departemen Onkologi Radiasi MRCCC Siloam Hospital Semanggi, pada kasus …
INTISARI PROGRAM STUDI SARJANA TERAPAN TEKNIK RADIODIAGNOSTIK DAN RADIOTERAPI POLITEKNIK KESEHATAN KEMENTERIAN KESEHATAN JAKARTA II SKRIPSI, 2020 TAUFIQURRAHMAN TEKNIK RADIOTERAPI VOLUMETRIC MODULATED ARC THERAPY (VMAT) PADA KASUS KANKER PARU DI DEPARTEMEN RADIOTERAPI MRCCC SILOAM SEMANGGI V BAB + 51 halaman + 29 gambar + 2 tabel + 11 lampiran Perkembangan teknik radioterapi terus berlanj…
SKRIPSI, 2019 YUDHA PERMANA ANALISIS CONFORMITY INDEX DAN HOMOGENEITY INDEX PADA TEKNIK PENYINARAN RADIOTERAPI 3D-CRT DAN IMRT DENGAN KASUS KANKER PAYUDARA DI RSUD PASAR MINGGU 5 BAB + 28 Halaman + 2 Gambar + 4 Tabel + 4 Grafik + Lampiran Penelitian ini bertujuan menganalisa nilai Conformity Index dan Homogeneity Index pada target volume berdasarkan hasil perencanaan penyinaran tek…
Val Naldo Ladibon Syahadatin, “Analisa Perbandingan Antara Sistem Piston Dengan Volume Reflector Dalam Menghantarkan Volume Tidal Pada Mesin Anestesi Ventilator” dibawah bimbingan Bapak Wadijanto, AIM, M. Si, 2016, 68 halaman.+ xviii + 17 Lampiran Penelitian ini bertujuan untuk membandingkan nilai output volume tidal dari dua sistem pemompaan udara yaitu, sistem volume reflector dan sis…
DEVI OCTAVIANA RESMA PAMUNGKAS (P2.31.30.1.13.040) PERBANDINGAN HASIL TREATMENT PLANNING SYSTEM TEKNIK PENYINARAN 3D CONFORMAL RADIOTHERAPY DENGAN 2 VARIASI 5 ARAH LAPANGAN RADIASI YANG BERBEDA PADA KASUS KANKER PROSTAT DI RSUPN DR. CIPTO MANGUNKUSUMO V Bab, 47halaman, 15gambar, 9 tabel, 7 grafik dan11 lampiran Penelitian ini bertujuan untuk membandingkan hasil TPS (treatment planning sy…
ARI YULI KRISTIAWAN PERBEDAAN HASIL TREATMENT PLANNING SYSTEM ANTARA TEKNIK RADIOTERAPI 3D CONFORMAL RADIATION THERAPY DAN INTENSITY MODULATED RADIATION THERAPY PADA KASUS KANKER CERVIX DI RSUPN CIPTO MANGUNKUSUMO xiv, 5 Bab, 42 halaman, 17 gambar, 6 tabel, dan 25 lampiran Penelitian ini bertujuan untuk menganalisis perbedaan hasil TPS (Treatment Planning System) antara teknik 3D CRT dan tek…
ABSTRAK Nurfajrian Husien. “Uji Banding Keakurasian Flow Sensor Spirolog yang Sudah Digunakan dan yang Baru Dalam Mencapai Parameter Volume Tidal Pada Alat Ventilator”, dibawah bimbingan Ansor Ibrahim Usman, ST., MT. 2019. 72 halaman + xviii + lampiran merupakan alat bantu pernafasan bertekanan negative atau positif yang menghasilkan udara terkontrol pada jalan nafas sehingga pasien mam…
Penelitian ini bertujuan untuk mengevaluasi prosedur pemeriksaan, teknik rekonstruksi dan hasil gambaran anatomi saluran pernapasan pada CT Scan Airway Pediatric. Desain penelitian ini adalah kualitatif deskriptif. Penelitian ini dilakukan di Departemen Radiologi Rumah Sakit Jantung dan Pembuluh Darah Harapan Kita bulan Februari sampai Mei 2018. Jumlah sampel pada penelitian ini sebanyak 5 pasi…
Signal to noise ratio (SNR) merupakan salah satu faktor penentu kualitas citra MRI. SNR didefinisikan sebagai perbandingan intensitas sinyal objek yang dilihat dengan noise. Ada beberapa faktor yang dapat mempengaruhi SNR, salah satunya coil radiofrekuensi. Pemeriksaan MRI genu berdasarkan literatur menggunakan volume coil yaitu coil genu. Sedangkan pada beberapa Rumah Sakit penggunaan coil saa…
Perkembangan teknik radioterapi terus berlanjut, salah satunya adalah teknik penyinaran Volumetric Modulated Arc Therapy (VMAT), di Departemen Radioterapi MRCCC Siloam Semanggi, untuk kasus kanker lidah penyinaran radiasi menggunakan teknik Volumetric Modulated Arc Therapy. Penelitian ini bertujuan untuk mendeskripsikan teknik radioterapi Volumetric Modulated Arc Therapy pada kasus kanker lid…
Tugas radioterapis memberikan treatment secara fraksinasi dengan efektif dan efisien diharapkan respon radiasi dapat dicapai untuk perubahan volume tumor sehingga prinsip dalam radioterapi untuk mematikan sebanyak mungkin sel kanker terpenuhi. Namun dikarenakan adanya faktor prognostik yang dapat mempengaruhi respon radiasi seperti Epstein–Barr Virus, sistem stadium TNM, tumor primer, usia pe…
ABSTRAK JURUSAN GIZI POLITEKNIK KESEHATAN KEMENKES JAKARTA II Tugas Akhir, Juni 2018 Aprilian Tri Wibowo GAMBARAN TINGKAT PARTISIPASI MASYARAKAT, CAKUPAN DISTRIBUSI KAPSUL VITAMIN A DAN PREVALENSI GIZI BURUK KURANG DI WILAYAH PUSKESMAS KECAMATAN CENGKARENG ix, 5 BAB, 84 Halaman, 15 Tabel, 4 Grafik, 8 Lampiran Tingkat kematian Balita erat hubungannya dengan status gizi. Indonesia meng…
Abstrack SKRIPSI, 2017 CLINTON JOHAN ADE WICAKSONO ANALISIS KUALITAS CITRA POTONGAN 4 CHAMBER MRI JANTUNG DENGAN DAN TANPA PENGGUNAAN SHIM VOLUME PADA SEQUENCE STEADY STATE FREE PRECESSION (SSFP) DI RUMAH SAKIT JANTUNG DAN PEMBULUH DARAH HARAPAN KITA V Bab + 42 halaman + 10 gambar + 8 tabel + 14 lampiran Penelitian bertujuan untuk menganalisis kualitas citra potongan 4 chamber MRI jantun…