REPOSITORY


POLTEKKES KEMENKES JAKARTA II

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
Help Information Statistik
Jelajahi ▼
Subject Year Author Prodi Jurusan Jenis
Home
Beranda Bantuan Informasi Statistik
No image available for this title
Penanda Bagikan

Publikasi Dosen

Pengaruh parameter Milliampere-Second (mAs) terhadap Kualitas Citra Dan Dosis Radiasi Pada Pemeriksaan Computed Tomography (CT) scan Kepala Pediatrik

Muhammad Irsal - Nama Orang; Guntur Winarno - Nama Orang;

ABSTRACT

Radiographers are responsible for administering radiation doses according to the principle of As Low As Reasonably Achievable (ALARA), to optimize the use of CT parameters to produce good image quality by minimizing radiation doses. The purpose of this study was to determine the effect of mAs parameters on image quality and radiation dose received by pediatric CT head examination patients. The research method to perform image processing results of examination using radiant viewer and analysis of value Contrast to noise ratio (CNR) as a parameter of image quality and CTDIvol to determine the estimated radiation dose, then an analysis is performed to determine whether there is an influence of mAs on the CNR and CTDIvol values. The mean value of kV 116 ± 8.28, the mean value of parameter mAs 161.5 ± 63.46, the mean SNR parameter value is 7.5 ± 0.8, the mean return value of CNR parameter was 0.318 ± 0.291, the mean value of the CTDIvol parameter is 18.68 mGy ± 4.55 mGy, the average value of DLP parameters was 408.7 mGy x cm ± 105.2 mGy x cm, the mean value of parameter DLP is 441.2 mGy x cm ± 155.2 mGy x cm. With linear regression analysis of test results between mAs to CNR is R2 = 0.045. then to the results of linear regression between mAs against CTDI is R2 = 0704, the estimated radiation dose limit for the average value of CTDIvol 18.68 mGy and the average value of DLP 408.7 mGy x cm, this means the protocol CT scan of the head of the pediatric use is still within safe limits by Diagnostic Reference Level of BAPETEN in 2018 to pediatric head CT examination

KEYWORDS : mAs; CNR; CTDIvol; Diagnsotic Reference Level


Ketersediaan
#
Kampus A 001
ART0000000000175
Tersedia namun tidak untuk dipinjamkan - For Reading
Informasi Detail
Judul Seri
-
No. Panggil
001
Penerbit
Kalimantan Selatan : FMIPA Universitas Lambung Mangkurat., 2020
Deskripsi Fisik
-
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
001
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
2021
Subjek
CNR
mAs
CTDIvol
Diagnsotic Reference Level
Info Detail Spesifik
Jurnal Fisika FLux: Jurnal Ilmiah FMIPA Universitas Lambung Mangkurat; https://ppjp.ulm.ac.id/journal/index.php/f/article/view/7085;DOI: https://doi.org/10.20527/flux.v17i1.7085
Pernyataan Tanggungjawab
-
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • Pengaruh parameter Milliampere-Second (mAs) terhadap Kualitas Citra Dan Dosis Radiasi Pada Pemeriksaan Computed Tomography (CT) scan Kepala Pediatrik
    Other Resource Link
  • Similarity- Pengaruh parameter Milliampere-Second (mAs) terhadap Kualitas Citra Dan Dosis Radiasi Pada Pemeriksaan Computed Tomography (CT) scan Kepala Pediatrik
Komentar

Anda harus masuk sebelum memberikan komentar


NPP 3174072C0000001

Link

  • Web Utama
  • Web Perpustakaan
  • Repository
  • KINK
  • Eresources PNRI

Kontak Kami

Perpustakaan Poltekkes Kemenkes Jakarta II
Jalan Hang Jebat III/F3 Kebayoran Baru Jakarta 12120

Telp.: +6221-7397641
Email: perpus@poltekkesjkt2.ac.id

Cari


Download

Tumbuh Bersama

Tumbuh bersaama kami dengan pengetahuan yang menakjubkan

Temukan, Pelajari, Berkembang

Perpustakaan, Membangkitkan Keajaiban Lintas Generasi

Nyalakan Masa Depan Anda

Alat dan Panduan untuk Perjalanan Setiap Pembelajar

Baca. Jelajahi. Raih

Dimana Imajinasi Menjadi Kenyataan


Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik