ABSTRACT BACHELOR OF APPLIED SCIENCE PROGRAM IMAGING RADIOLOGY TECHNOLOGY STUDY PROGRAM RADIODIAGNOSTICS AND RADIOTHERAPY DEPARTMENT HEALTH POLYTECHNIC OF HEALTH MINISTRY JAKARTA II THESIS,2025 ANNISA YUMNA FALSAFI ANALYSIS OF ABDOMINAL CT ANGIOGRAPHY TECHNIQUES FOLLOWING ENDOVASCULAR ANEURYSM REPAIR (EVAR) IN ABDOMINAL AORTIC ANEURYSM CASES UNDERTAKEN AT MEURAXA REGIONAL GENERAL …
In producing a good radiographic image, an optimization method is needed. This study was conducted to seek optimization of the radiographic examination of the manus ossa with objective and subjective image quality analysis. The research method is quantitative experimental, using a variety of exposure factors: 40kV 4 mAs, 40kV 10 mAs, 46 kV 5 mAs, 53 kV 2,5 mAs, 61kV 1,25 mAs. Then an object…
Kontras radiografi adalah perbedaan yang terlihat antara dua organ dengan densitas yang berdekatan atau mungkin berbeda. Kontras radiografi yang optimal akan memperjelas batas dari suatu organ. Tegangan tabung (kV) merupakan faktor utama dalam mengendalikan kontras radiografi, karena menentukan kualitas radiasi sinar-X yang dihasilkan untuk dapat menembus suatu bahan/objek. Penelitian ini bertu…
INTISARI PROGRAM STUDI DIPLOMA 4 TEKNIK RADIODIAGNOSTIK DAN RADIOTERAPI POLITEKNIK KESEHATAN KEMENTRIAN KESEHATAN JAKARTA II SKRIPSI, 2019 BRYLLIAN PUTRA PAMUNGKAS VARIASI SLICE THICKNESS UNTUK MENGHASILKAN IMAGE QUALITY PADA PEMERIKSAAN CT SCAN KEPALA DI RUMAH SAKIT UMUM DAERAH TARAKAN 5 BAB + 31 halaman + 12 gambar + 2 tabel + lampiran Penelitian ini bertujuan untuk mencari batas…
MUHAMMAD RIVAL ALFAJRI (P.2.114.021.8.036) EVALUASI PENGGUNAAN FAKTOR EKSPOSI PEMERIKSAAN OSSA MANUS MENGGUNAKAN STEPWEDGE xiv, V BAB, 76 HALAMAN, 16 GAMBAR, 8 TABEL Tujuan : melakukan analisa pengaruh faktor eksposi terhadap kualitas citra pada pemeriksaan ossa manus, metode : penelitian dilakukan dengan metode eksperimen kuantitatif, dengan melakukan variasi faktor eksposi : 40kV 4 mAs, …
Background: Cardiac MRI examination is relatively rare in Indonesia. The effect of the use of volume shim on moving organs, such as the heart is relatively unknown and noticed by radiographers and cardiologists. Objective: To analyse the image quality of 4 chamber sections of Cardiac Magnetic Resonance Imaging with and without the use of shim volume on Steady State Free Precession (SSFP) sequen…
ABSTRACT BACHELOR OF APPLIED SCIENCE STUDY PROGRAM DEPARTMENT OF RADIOLOGY IMAGING TECHNOLOGY POLITEKNIK KESEHATAN KEMENTERIAN KESEHATAN JAKARTA II THESIS, 2020 ANDHIKA PRAYOGA ADITYA PRATAMA COMPARISON OF FAT SUPPRESSION TECHNIQUE T2 STIR AND T2 DIXON IN MR IMAGE QUALITY OF KNEE JOINT MRI IN CORONAL SLICES 5 Chapters + 28 Pages + 20 Pictures + 2 Tables + Attachment This research ai…