REPOSITORY


POLTEKKES KEMENKES JAKARTA II

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
Help Information Statistik
Jelajahi ▼
Subject Year Author Prodi Jurusan Jenis
Home
Beranda Bantuan Informasi Statistik
No image available for this title
Penanda Bagikan

Dokumen

MRI Case Report of Perianal Fistula with T2 TSE SPIR Sequence

Nursama Heru Apriantoro - Nama Orang; Arif Rohman Saleh - Nama Orang; Gandosari - Nama Orang; Puji Supriyono - Nama Orang; Mahfud Edy Widiatmoko - Nama Orang;

MRI is a diagnostic imaging tool crucial for pelvic examination in perianal fistula cases. MRI
imaging offers some advantages, especially in showing the area of spesi and secondary dilatation.
Both have a high recurrence rate after surgery and an important role in determining surgical
outcomes and minimizing complications. This study aims to evaluate pelvic MRI examination of
perianal fistulas using the T2 TSE SPIR (Turbo Spin Echo Spectral Presaturation with Inversion
Recovery) sequence. Research design used a qualitative descriptive method with participatory
observation through a case study approach to Perianal Fistula using T2 TSE_SPIR. It was carried
out at the Radiology Department of Mayapada Hospital in South Jakarta from August to
December 2022. The MRI equipment Philips Achieva 1.5 Tesla with Sense Body Coil. MRI
contrast agent of gadoteric acid, Vitamin E capsule, was attached to the perianal fistula location
to make it easier for the radiologist to see the path of the perianal fistula. The results of Pelvis
MRI images in perianal fistulas using the T2 TSE SPIR sequence shown with clear boundaries of
perianal fistulas with anal organs, sigmoid colon, bladder, and prostate between one organ and
another. Implementing the selection of the T2 TSE SPIR sequence to visualize fluid images
becomes hyper-intensive by suppressing fat signals so that only fluid is visible in the perianal
abscess and fistula images.


Ketersediaan
#
Kampus A 651.5
ADM0000000000192
Tersedia namun tidak untuk dipinjamkan - For Reading
Informasi Detail
Judul Seri
-
No. Panggil
651.5
Penerbit
: ., 2023
Deskripsi Fisik
-
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
651.5
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
2023
Subjek
Cek Similarity
Info Detail Spesifik
Hasil Cek Turnitin Artikel MRI Case Report of Perianal Fistula with T2 TSE SPIR Sequence
Pernyataan Tanggungjawab
-
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • CEK TURNITIN ARTIKEL MRI Case Report of Perianal Fistula with T2 TSE SPIR Sequence
  • KORESPONDENSI ARTIKEL MRI Case Report of Perianal Fistula with T2 TSE SPIR Sequence
    Lembaran ini berisi lembaran korespondensi artikel MRI Case Report of Perianal Fistula with T2 TSE SPIR Sequence
  • MRI Case Report of Perianal Fistula with T2 TSE SPIR Sequence
    MRI is a diagnostic imaging tool crucial for pelvic examination in perianal fistula cases. MRI imaging offers some advantages, especially in showing the area of spesi and secondary dilatation. Both have a high recurrence rate after surgery and an important role in determining surgical outcomes and minimizing complications. This study aims to evaluate pelvic MRI examination of perianal fistulas using the T2 TSE SPIR (Turbo Spin Echo Spectral Presaturation with Inversion Recovery) sequence. Research design used a qualitative descriptive method with participatory observation through a case study approach to Perianal Fistula using T2 TSE_SPIR. It was carried out at the Radiology Department of Mayapada Hospital in South Jakarta from August to December 2022. The MRI equipment Philips Achieva 1.5 Tesla with Sense Body Coil. MRI contrast agent of gadoteric acid, Vitamin E capsule, was attached to the perianal fistula location to make it easier for the radiologist to see the path of the perianal fistula. The results of Pelvis MRI images in perianal fistulas using the T2 TSE SPIR sequence shown with clear boundaries of perianal fistulas with anal organs, sigmoid colon, bladder, and prostate between one organ and another. Implementing the selection of the T2 TSE SPIR sequence to visualize fluid images becomes hyper-intensive by suppressing fat signals so that only fluid is visible in the perianal abscess and fistula images.
Komentar

Anda harus masuk sebelum memberikan komentar


NPP 3174072C0000001

Link

  • Web Utama
  • Web Perpustakaan
  • Repository
  • KINK
  • Eresources PNRI

Kontak Kami

Perpustakaan Poltekkes Kemenkes Jakarta II
Jalan Hang Jebat III/F3 Kebayoran Baru Jakarta 12120

Telp.: +6221-7397641
Email: perpus@poltekkesjkt2.ac.id

Cari


Download

Tumbuh Bersama

Tumbuh bersaama kami dengan pengetahuan yang menakjubkan

Temukan, Pelajari, Berkembang

Perpustakaan, Membangkitkan Keajaiban Lintas Generasi

Nyalakan Masa Depan Anda

Alat dan Panduan untuk Perjalanan Setiap Pembelajar

Baca. Jelajahi. Raih

Dimana Imajinasi Menjadi Kenyataan


Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik