REPOSITORY


POLTEKKES KEMENKES JAKARTA II

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
Help Information Statistik
Jelajahi ▼
Subject Year Author Prodi Jurusan Jenis
Home
Beranda Bantuan Informasi Statistik
No image available for this title
Penanda Bagikan

Publikasi Dosen

Image Quality Differences In CT Scan Thorax By Using Slice Thickness Variation

Samsun - Nama Orang; Legia Prananto - Nama Orang; Novita Wulandari - Nama Orang;

The picture quality get from CT Scan of Thorax which required optimal parameter selection that’s right, one of them the selection of slice thickness. The method taken from theses that have been publish in the year 2013. The results of the research show the percentage of the value of the average spatial resolution of 2.5 mm slice thickness is (33.3%), noise (17.8%), artefact (1%). On the thickness of the slices 5 mm spatial resolution is (17%), noise (8.9%), artefacts (0%). On the thickness of slices of 7.5 mm spatial resolution is (8.9%), noise (11.1%), artefacts (53.3%). While the thickness of the slices the spatial resolution is 10 mm (8.9%), noise (22.2%), artefacts (68.9%). Based on the research results obtained the conclusion that thickness 2.5 mm slices on Thorax CT-Scan images produce better picture quality than with the thickness of the slices 5 mm, 7.5 mm, 10 mm, because the spatial resolution is more clear so as to reduce noise and artifacts.


Ketersediaan
#
Kampus A 001.43
ART0000000000572
Tersedia namun tidak untuk dipinjamkan - For Reading
Informasi Detail
Judul Seri
-
No. Panggil
001.43
Penerbit
Jakarta : Poltekes Jakarta II., 2017
Deskripsi Fisik
-
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
001.43
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
-
Subjek
CT Scan Thorax
thick slices
picture quality
Info Detail Spesifik
Publikasi pada Sanitas - Jurnal Teknologi dan Seni Kesehatan ; Vol 8 No 2 (2017): SANITAS Volume 8 Nomor 2 Tahun 2017 ; https://doi.org/10.36525/sanitas.2017.13https://poltekkesjkt2.ac.id/id/ ; https://sanitas.ejournal.id/index.php/SANITA S/article/view/20171201samsun
Pernyataan Tanggungjawab
-
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • Image Quality Differences In CT Scan Thorax By Using Slice Thickness Variation
    Other Resource Link
Komentar

Anda harus masuk sebelum memberikan komentar


NPP 3174072C0000001

Link

  • Web Utama
  • Web Perpustakaan
  • Repository
  • KINK
  • Eresources PNRI

Kontak Kami

Perpustakaan Poltekkes Kemenkes Jakarta II
Jalan Hang Jebat III/F3 Kebayoran Baru Jakarta 12120

Telp.: +6221-7397641
Email: perpus@poltekkesjkt2.ac.id

Cari


Download

Tumbuh Bersama

Tumbuh bersaama kami dengan pengetahuan yang menakjubkan

Temukan, Pelajari, Berkembang

Perpustakaan, Membangkitkan Keajaiban Lintas Generasi

Nyalakan Masa Depan Anda

Alat dan Panduan untuk Perjalanan Setiap Pembelajar

Baca. Jelajahi. Raih

Dimana Imajinasi Menjadi Kenyataan


Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik