Publikasi Dosen
Augmented Reality as the Medical Electronic Equipment Inventory Identifier
ABSTRACT Background: Inventory systems are very numerous and require a long time when rechecking. In doing a shortcut time for checking, it can be done the application of augmented reality. Methods: This research can be applied to all types and brands of smartphones. The testing was carried out using three different types and brands of smartphones in three conditions: dark rooms, bright room and open spaces for three times for each smartphone. It examines the suitability of displaying asset objects such as Infusion Device Analyzer (IDA-1), Electrical Safety Analyzer (ISA) and Piranha radiology high voltage tester with target objects using existing inventory labels also Barbarian with the target a book cover with the distance 10, 15, 20, 25 and 30 cm. Results: By using three different types and brands of smartphones: A, B and C, the incompatibility result percentage of the asset object with the target object is obtained. The average of incompatibility result of Smartphone A, B, and C for the ISA asset object is 83%. The average of incompatibility result of Smartphone A, B, and C for the IDA asset object is 71%, The average of incompatibility result of Smartphone A, B, and C for the Piranha asset object is 36%, For the whole result for Barbarian object asset is 100%. Conclusions: Making augmented reality has been successfully carried out with 3D models but there is a discrepancy between the appearance of asset objects with the target object except for the book cover and barbarian. Keywords: Augmented reality, , Medical electronic equipment, inventory, Identifier
Tidak tersedia versi lain