Image of Pengaruh Variasi Penggunaan Tipe Pulsa Selective Water Excitation Terhadap Kualitas Citra MRI KNEE Joint Pada Sequence 3D Watsc
Bookmark Share

Skripsi

Pengaruh Variasi Penggunaan Tipe Pulsa Selective Water Excitation Terhadap Kualitas Citra MRI KNEE Joint Pada Sequence 3D Watsc

KARISMA ROFIQO - Personal Name;

INTISARI
PROGRAM STUDI DIPLOMA 4 TEKNIK RADIODIAGNOSTIK DAN RADIOTERAPI POLITEKNIK KESEHATAN KEMENTERIAN KESEHATAN JAKARTA II
SKRIPSI, 2019
KARISMA ROFIQO
PENGARUH VARIASI PENGGUNAAN TIPE PULSA SELECTIVE WATER EXCITATION TERHADAP KUALITAS CITRA MRI KNEE JOINT PADA SEQUENCE 3D WATSC
5 bab + 56 halaman + 31 gambar + 9 lampiran
Penelitian ini bertujuan untuk menganalisa pengaruh variasi penggunaan tipe pulsa selective water excitation terhadap kualitas citra berupa signal to noise ratio (SNR)
pada MRI knee joint dengan sequence 3D WATSc. Desain penelitian ini adalah kuantitatif analitik yang berupa pengamatan atau observasi di lapangan dan eksperimen pada bulan Maret sampai April 2019 di RS Premier Bintaro. Menggunakan instrumen penelitian berupa lembar kerja, komputer untuk ROI dan lembar pengukuran. Dengan populasi penelitian diambil dari seluruh jumlah pemeriksaan MRI knee joint dengan jumlah sampel sebanyak 10. Data diolah dan diambil secara primer.
Dari hasil dengan 10 sampel penelitian didapatkan hasil bahwa pemeriksaan MRI knee joint potongan axial dengan variasi tipe pulsa selective water excitation 11, 121 dan
1331 pada sequence 3D WATSc berpengaruh terhadap SNR (signal to noise ratio).
Berdasarkan hasil penelitian yang telah dilakukan, tipe pulsa SWE 1331 memiliki rata- rata ranking SNR tertinggi yaitu 2,70. Sedangkan, rata-rata ranking SNR terendah berada pada tipe pulsa SWE 11. Hasil citra yang dihasilkan oleh tipe pulsa SWE 11 cenderung hiperintens, sedangkan tipe pulsa SWE 1331 hipointens. Semakin panjang elemen dari tipe pulsa SWE tersebut, semakin tinggi rata-rata SNR yang dihasilkannya.
Kata Kunci :Magnetic Resonance Imaging, MRI Knee Joint, Selective Water Excitation,
Signal to Noise Ratio
Daftar Bacaan : 10 buku + 18 jurnal


Availability
#
Kampus A 001.43 TRO-D4-2019 Rof p
AK00000000001238
Available but not for loan - For Reading
Detail Information
Series Title
-
Call Number
001.43 TRO-D4- 2019 Rof p
Publisher
Jakarta poltekes jakarta II : ., 2019
Collation
-
Language
Indonesia
ISBN/ISSN
-
Classification
001.43
Content Type
-
Media Type
-
Carrier Type
-
Edition
2019
Subject(s)
MRI Knee Joint
Selective Water Excitation
Magnetic Resonance Imaging
Specific Detail Info
Legia Prananto (P1),Guntur Winarno (P2),Prodi D4 TRO
Statement of Responsibility
-
Other version/related

No other version available

File Attachment
  • PENGARUH VARIASI PENGGUNAAN TIPE PULSA SELECTIVE WATER EXCITATION TERHADAP KUALITAS CITRA MRI KNEE JOINT PADA SEQUENCE 3D WATSC
Comments

You must be logged in to post a comment


NPP 3174072C0000001

Link

  • Web Utama
  • Web Perpustakaan
  • Repository
  • KINK
  • Eresources PNRI

Kontak Kami

Perpustakaan Poltekkes Kemenkes Jakarta II
Jalan Hang Jebat III/F3 Kebayoran Baru Jakarta 12120

Telp.: +6221-7397641
Email: perpus@poltekkesjkt2.ac.id

Search


Download

Tumbuh Bersama

Tumbuh bersaama kami dengan pengetahuan yang menakjubkan

Temukan, Pelajari, Berkembang

Perpustakaan, Membangkitkan Keajaiban Lintas Generasi

Nyalakan Masa Depan Anda

Alat dan Panduan untuk Perjalanan Setiap Pembelajar

Baca. Jelajahi. Raih

Dimana Imajinasi Menjadi Kenyataan


Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search