Perbandingan Teknik Fat Suppression TIRM dan Dixon terhadap Citra MRI Knee Joint Potongan Sagital di RSUP Fatmawati Pada MRI Seimens Essenza 1.5 Tesla
This study aims to analyze the fat suppression technique of TIRM and Dixon in displaying the anatomical image of knee joint on MRI examination.
The research method used is quantitative analytics with data collection method is the observation conducted from March to April 2018 in Fatmawati General Hospital. Research instruments used, namely worksheet and questionnaire sheet. The sample amounted to 20 patients. Then the two image results were compared by assessing meniscus, cartilage, muscle, overall image quality and using the Wilcoxon Two Sample test of 6 respondents.
The result of this research is meniscus showing that there is significant difference between fat suppression technique TIRM and Dixon, with p value = 0.00 (p 0.05), then H0 is accepted. In result of muscle picture showed that there is significant difference between fat suppression technique TIRM and Dixon, p value = 0.02 (p