Image of Evaluasi Verifikasi Geometri pada Klinis Kanker Servik Teknik 3 Dimensional Conformal Radiotherapy (3D-CRT) Menggunakan Alat Electronic Portal Imaging Devices (EPID)
Bookmark Share

Skripsi

Evaluasi Verifikasi Geometri pada Klinis Kanker Servik Teknik 3 Dimensional Conformal Radiotherapy (3D-CRT) Menggunakan Alat Electronic Portal Imaging Devices (EPID)

Maulyna Prabuditya Aini - Personal Name;

Verification is an important component of radiotherapy aimed at obtaining data on the variations that occur during a patient undergoing radiation. Verification of Cervical Cancer The 3D-CRT technique is performed on a multiple of 5 fractions using the Electronic Portal Imaging Devices (EPID).
      The purpose of this study was to evaluate the geometrical verification of cervical cancer the 3 Dimensional Conformal Radiotherapy (3D-CRT) tecnique using Electronic Portal Imaging Devices (EPID). The design of this research is descriptive quantitative, with the method of observation and interview.
      The study was conducted at Radiotherapy Installation in Dharmais Cancer Hospital using primary data in March until April 2018.
      Data collection method was done by field observation and interview to radiotherapist. The research instrument used primary data of verification result, worksheet and interview guide.
      Processing and analysis of data obtained through direct observation and interviews, by looking at verification management procedures, comparing the results of verification with the limits of tolerance that exist in the theory, and know the cause of the radiation field shift in cases of cervical cancer the 3 Dimensional Conformal Radiotherapy (3D-CRT ) tecnique. The result is still frequent radiation shifts that exceed the tolerance limit and the dominant cause of the radiation field shift is the marker on the shifting skin and the patient's positioning.


Availability
#
Kampus A 001-43 TRO-D4-2018 Ain e
AK0000000000851
Available but not for loan - For Reading
Detail Information
Series Title
-
Call Number
001-43 TRO-D4-2018 Ain e
Publisher
Jakarta : Jurusan Teknik Radiodiagnostik dan Radioterapi., 2018
Collation
-
Language
Indonesia
ISBN/ISSN
-
Classification
001-43
Content Type
-
Media Type
-
Carrier Type
-
Edition
2018
Subject(s)
Verification, Cervical Cacer
EPID, Radioterapy, 3D-CRT
Radioterafi
Specific Detail Info
Eny Suprianingsih ( P1 ), Shinta Gunawati Sutoro ( P2 ), D-IV-TRO
Statement of Responsibility
-
Other version/related

No other version available

File Attachment
  • Evaluasi Verifikasi Geometri pada Klinis Kanker Servik Teknik 3 Dimensional Conformal Radiotherapy (3D-CRT) Menggunakan Alat Electronic Portal Imaging Devices (EPID)
Comments

You must be logged in to post a comment


NPP 3174072C0000001

Link

  • Web Utama
  • Web Perpustakaan
  • Repository
  • KINK
  • Eresources PNRI

Kontak Kami

Perpustakaan Poltekkes Kemenkes Jakarta II
Jalan Hang Jebat III/F3 Kebayoran Baru Jakarta 12120

Telp.: +6221-7397641
Email: perpus@poltekkesjkt2.ac.id

Search


Download

Tumbuh Bersama

Tumbuh bersaama kami dengan pengetahuan yang menakjubkan

Temukan, Pelajari, Berkembang

Perpustakaan, Membangkitkan Keajaiban Lintas Generasi

Nyalakan Masa Depan Anda

Alat dan Panduan untuk Perjalanan Setiap Pembelajar

Baca. Jelajahi. Raih

Dimana Imajinasi Menjadi Kenyataan


Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search