REPOSITORY


POLTEKKES KEMENKES JAKARTA II

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
Help Information Statistik
Jelajahi ▼
Subject Year Author Prodi Jurusan Jenis
Home
Beranda Bantuan Informasi Statistik
Image of Evaluasi Verifikasi Geometri pada Klinis Kanker Servik Teknik 3 Dimensional Conformal Radiotherapy (3D-CRT) Menggunakan Alat Electronic Portal Imaging Devices (EPID)
Penanda Bagikan

Skripsi

Evaluasi Verifikasi Geometri pada Klinis Kanker Servik Teknik 3 Dimensional Conformal Radiotherapy (3D-CRT) Menggunakan Alat Electronic Portal Imaging Devices (EPID)

Maulyna Prabuditya Aini - Nama Orang;

Verification is an important component of radiotherapy aimed at obtaining data on the variations that occur during a patient undergoing radiation. Verification of Cervical Cancer The 3D-CRT technique is performed on a multiple of 5 fractions using the Electronic Portal Imaging Devices (EPID).
      The purpose of this study was to evaluate the geometrical verification of cervical cancer the 3 Dimensional Conformal Radiotherapy (3D-CRT) tecnique using Electronic Portal Imaging Devices (EPID). The design of this research is descriptive quantitative, with the method of observation and interview.
      The study was conducted at Radiotherapy Installation in Dharmais Cancer Hospital using primary data in March until April 2018.
      Data collection method was done by field observation and interview to radiotherapist. The research instrument used primary data of verification result, worksheet and interview guide.
      Processing and analysis of data obtained through direct observation and interviews, by looking at verification management procedures, comparing the results of verification with the limits of tolerance that exist in the theory, and know the cause of the radiation field shift in cases of cervical cancer the 3 Dimensional Conformal Radiotherapy (3D-CRT ) tecnique. The result is still frequent radiation shifts that exceed the tolerance limit and the dominant cause of the radiation field shift is the marker on the shifting skin and the patient's positioning.


Ketersediaan
#
Kampus A 001-43 TRO-D4-2018 Ain e
AK0000000000851
Tersedia namun tidak untuk dipinjamkan - For Reading
Informasi Detail
Judul Seri
-
No. Panggil
001-43 TRO-D4-2018 Ain e
Penerbit
Jakarta : Jurusan Teknik Radiodiagnostik dan Radioterapi., 2018
Deskripsi Fisik
-
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
001-43
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
2018
Subjek
Verification, Cervical Cacer
EPID, Radioterapy, 3D-CRT
Radioterafi
Info Detail Spesifik
Eny Suprianingsih ( P1 ), Shinta Gunawati Sutoro ( P2 ), D-IV-TRO
Pernyataan Tanggungjawab
-
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • Evaluasi Verifikasi Geometri pada Klinis Kanker Servik Teknik 3 Dimensional Conformal Radiotherapy (3D-CRT) Menggunakan Alat Electronic Portal Imaging Devices (EPID)
Komentar

Anda harus masuk sebelum memberikan komentar


NPP 3174072C0000001

Link

  • Web Utama
  • Web Perpustakaan
  • Repository
  • KINK
  • Eresources PNRI

Kontak Kami

Perpustakaan Poltekkes Kemenkes Jakarta II
Jalan Hang Jebat III/F3 Kebayoran Baru Jakarta 12120

Telp.: +6221-7397641
Email: perpus@poltekkesjkt2.ac.id

Cari


Download

Tumbuh Bersama

Tumbuh bersaama kami dengan pengetahuan yang menakjubkan

Temukan, Pelajari, Berkembang

Perpustakaan, Membangkitkan Keajaiban Lintas Generasi

Nyalakan Masa Depan Anda

Alat dan Panduan untuk Perjalanan Setiap Pembelajar

Baca. Jelajahi. Raih

Dimana Imajinasi Menjadi Kenyataan


Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik