Image of EVALUASI NILAI DIAGNOSTIK REFERENCE LEVEL (DRL)  PADA CT SCAN UROGRAFI NON KONTRAS DI RSUD BUDHI ASIH
Bookmark Share

Skripsi

EVALUASI NILAI DIAGNOSTIK REFERENCE LEVEL (DRL) PADA CT SCAN UROGRAFI NON KONTRAS DI RSUD BUDHI ASIH

DIANA PUSPITASARI - Personal Name;

Diagnostically, Non-contrast CT urography is the diagnostic standard for evaluating the urinary tract. With the increasing demand for CT urography examinations, the need for optimal image quality and appropriate radiation dose has become increasingly important. Therefore, efforts to optimize radiation protection in CT urography examinations are essential. In relation to which, as part of radiation protection optimization effort, it is necessary to establish and calculate Diagnostic Reference Levels (DRLs) for CT urography examinations.
This research aims to evaluate the results of Diagnostic Reference Level (DRL) calculations based on the CT dose index volume (CTDIvol) and dose length product (DLP) in patients undergoing non-contrast CT urography examinations.
Research design used applies a descriptive quantitative design with an observational approach. The research was conducted starting from November up to December 2024, with a purposive sampling of 80 data points based on specific criteria. Thereafter, the collected data were processed using Microsoft Excel, and the calculated CTDIvol and the DLP values were compared to the Indonesian Diagnostic Reference Level (I-DRL) standards.
Results of research indicate that the Diagnostic Reference Level (DRL) values for non-contrast CT urography examinations carried out at Radiology Department of Budhi Asih Regional General Hospital are below the Indonesian Diagnostic Reference Level (I-DRL) established by Nuclear Energy Regulatory Agency of Indonesia (BAPETEN). This finding suggests that the radiation dose in Budhi Asih Hospital remains within safe limits. Hence, the DRL values for non-contrast CT urography can be accordingly established namely CTDIvol is 5.5775 mGy and DLP is 302.4925 mGy·cm

Keywords : Non-Contrast CT Urography, Diagnostic Reference Level, CTDI, DLP.
Reference List : 25 Journals, 11 Books (2016–2023).


Availability
#
Kampus A 001.43 TRO-D4-2025 DIA e
AK00000000544455
Available but not for loan - For Reading
Detail Information
Series Title
-
Call Number
001.43 TRO-D4-2025 DIA e
Publisher
Jakarta : Poltekkes Kemenkes Jakarta II., 2025
Collation
-
Language
Indonesia
ISBN/ISSN
-
Classification
001.43
Content Type
-
Media Type
-
Carrier Type
-
Edition
2025
Subject(s)
jurtro
Diagnostik Reference Level
Specific Detail Info
SRIYATUN(P1); ASUMSIE TARIGAN(P2);MAHFUD EDY WIDIATMOKO(P3);LEGIA PRANANTO(P4);D4-TRO-2025:P21130223922
Statement of Responsibility
-
Other version/related

No other version available

File Attachment
  • Please login to see this attachment
Comments

You must be logged in to post a comment


NPP 3174072C0000001

Link

  • Web Utama
  • Web Perpustakaan
  • Repository
  • KINK
  • Eresources PNRI

Kontak Kami

Perpustakaan Poltekkes Kemenkes Jakarta II
Jalan Hang Jebat III/F3 Kebayoran Baru Jakarta 12120

Telp.: +6221-7397641
Email: perpus@poltekkesjkt2.ac.id

Search


Download

Tumbuh Bersama

Tumbuh bersaama kami dengan pengetahuan yang menakjubkan

Temukan, Pelajari, Berkembang

Perpustakaan, Membangkitkan Keajaiban Lintas Generasi

Nyalakan Masa Depan Anda

Alat dan Panduan untuk Perjalanan Setiap Pembelajar

Baca. Jelajahi. Raih

Dimana Imajinasi Menjadi Kenyataan


Select the topic you are interested in
  • Computer Science, Information & General Works
  • Philosophy & Psychology
  • Religion
  • Social Sciences
  • Language
  • Pure Science
  • Applied Sciences
  • Art & Recreation
  • Literature
  • History & Geography
Icons made by Freepik from www.flaticon.com
Advanced Search