REPOSITORY


POLTEKKES KEMENKES JAKARTA II

Pencarian berdasarkan :

SEMUA Pengarang Subjek ISBN/ISSN Pencarian Spesifik

Pencarian terakhir:

{{tmpObj[k].text}}
Help Information Statistik
Jelajahi ▼
Subject Year Author Prodi Jurusan Jenis
Home
Beranda Bantuan Informasi Statistik
Image of PENGUKURAN MODULATION TRANSFER FUNCTION PADA PROTOKOL CT SCAN KEPALA DENGAN VARIASI ARUS WAKTU TABUNG DAN IDOSE
Penanda Bagikan

Skripsi

PENGUKURAN MODULATION TRANSFER FUNCTION PADA PROTOKOL CT SCAN KEPALA DENGAN VARIASI ARUS WAKTU TABUNG DAN IDOSE

IKHWAN ZIKRI - Nama Orang;

ABSTRACT
BACHELOR OF APPLIED SCIENCE PROGRAM
IMAGING RADIOLOGY TECHNOLOGY STUDY PROGRAM
RADIODIAGNOSTICS AND RADIOTHERAPY DEPARTMENT
HEALTH POLYTECHNIC OF HEALTH MINISTRY
JAKARTA II
THESIS, 2025
IKHWAN ZIKRI
“MEASUREMENT OF MODULATION TRANSFER FUNCTION IN HEAD CT SCAN
PROTOCOL WITH VARIATIONS IN TUBE CURRENT TIME AND IDOSE”
V Chapters + 32 Pages + 9 Images + 2 Table + 8 Attachments
Background: radiologically, in the efforts to optimize head CT scan protocols, variations in tube
current and the use of iterative reconstruction (IR) are often combined to reduce patient radiation
dose, which may impact image quality and radiation exposure. In relation to which, the
Modulation Transfer Function (MTF) is an objective measurement used to assess spatial resolution
in CT images. It is expected to provide valuable information on image quality while striving to
achieve the lowest possible radiation dose.
Research Methods: this research applies descriptive quantitative method using a head CT scan
protocol applied to a CT quality control phantom with variations in tube current settings of 200
mA and 300 mA, combined with iDose. Furthermore, analysis was performed on 10 image slices,
and the 50% Modulation Transfer Function (MTF) values were calculated using ImageJ software.
Further analysis was conducted to evaluate the effect of tube current variations combined with
iterative reconstruction (IR) on the 50% MTF values.
Results: the research found that the MTF values for different tube current settings and their
combinations with iterative reconstruction (IR) tended to remain consistent across all 50% MTF
values, regardless of whether the tube current was set at 200 mA or 300 mA, with or without the
combination of IR.
Keywords : Modulation Transfer Function (MTF), Head CT Protocol, Tube
Current,Iterative Reconstruction (IR).


Ketersediaan
#
Kampus A 001.43 TRO-D4-2025 IKH p
AK00000000544429
Tersedia namun tidak untuk dipinjamkan - For Reading
Informasi Detail
Judul Seri
-
No. Panggil
001.43 TRO-D4-2025 IKH p
Penerbit
: Jurusan Teknik Radiodiagnostik dan Radioterapi., 2025
Deskripsi Fisik
-
Bahasa
Indonesia
ISBN/ISSN
-
Klasifikasi
001.43 TRO
Tipe Isi
-
Tipe Media
-
Tipe Pembawa
-
Edisi
2025
Subjek
Modulation Transfers Function (MTF)
Protokol CT Kepala
Arus Tabung
Iterative Reconstruction (IR)
Info Detail Spesifik
Muhammad Irsal(P1); Shinta Gunawati(P2); Guntur Winarno(P3); D4-TRO-2025: P21130223950
Pernyataan Tanggungjawab
-
Versi lain/terkait

Tidak tersedia versi lain

Lampiran Berkas
  • Harap masuk untuk melihat lampiran
  • Harap masuk untuk melihat lampiran
Komentar

Anda harus masuk sebelum memberikan komentar


NPP 3174072C0000001

Link

  • Web Utama
  • Web Perpustakaan
  • Repository
  • KINK
  • Eresources PNRI

Kontak Kami

Perpustakaan Poltekkes Kemenkes Jakarta II
Jalan Hang Jebat III/F3 Kebayoran Baru Jakarta 12120

Telp.: +6221-7397641
Email: perpus@poltekkesjkt2.ac.id

Cari


Download

Tumbuh Bersama

Tumbuh bersaama kami dengan pengetahuan yang menakjubkan

Temukan, Pelajari, Berkembang

Perpustakaan, Membangkitkan Keajaiban Lintas Generasi

Nyalakan Masa Depan Anda

Alat dan Panduan untuk Perjalanan Setiap Pembelajar

Baca. Jelajahi. Raih

Dimana Imajinasi Menjadi Kenyataan


Pilih subjek yang menarik bagi Anda
  • Karya Umum
  • Filsafat
  • Agama
  • Ilmu-ilmu Sosial
  • Bahasa
  • Ilmu-ilmu Murni
  • Ilmu-ilmu Terapan
  • Kesenian, Hiburan, dan Olahraga
  • Kesusastraan
  • Geografi dan Sejarah
Icons made by Freepik from www.flaticon.com
Pencarian Spesifik